By Sarah Bartash
EDS engineers are able to enhance their designs and do away with rework at the end of the design cycle thanks to Siemens Capital Analysis.
It’s getting more and harder to ensure new cars are both economical and safe. The automotive industry is investing in more sophisticated and electrified technologies in response to market needs for performance, sustainability, and secure tailored services. Assurance of product safety for new generation products with complex power distribution architectures and sophisticated automated systems is the main concern facing automobile OEMs and suppliers.
However, the conventional method of examining fuse and wire sizing under stress or failure situations, as well as validating electrical schematic connectivity, is frequently a time-consuming, manual procedure. The danger of mistakes and non-compliance might be increased by this manual technique, which can be a major bottleneck. And here’s the real issue: In 2020, a research published by the National Fire Protection Association found that non-compliance with electrical distribution architecture was the primary cause of highway vehicle fires.
How can this be fixed? transferring knowledge about EDS compliance to an automated analysis engine and integrating it with a model-based design framework. By doing this, EDS engineers are able to obtain feedback and insights early in the design cycle, which helps them to guarantee that safety and design requirements are met and to increase design accuracy.
In this blog, we’ll examine how EDS engineers may enhance their designs and reduce rework at the end of the design cycle with the help of Siemens Capital Analysis, a potent part of the Capital software suite for electrical and electronic (E/E) systems development.
Creating electricity distribution systems is a multifaceted, intricate process. A large portion of design analysis has traditionally been done by hand; physical prototype inspections happen late in the development process, necessitating costly and time-consuming late-stage rework. Fixing problems thus late in the development process might result in significant delays and jeopardize the program as a whole.
Take into consideration a different strategy that, by moving design research to the left and permitting iterations early in the development lifecycle, eliminates last-minute adjustments. By using this method, you can find mistakes and faults before physical prototypes and schematics are finalized, when they can be fixed more easily and affordably. The following example illustrates how this could appear:
EDS engineers would be able to continuously review and refine their designs within the design environment, ensuring that their designs are compliant before proceeding into the prototyping stage, if compliance engineering skills could be utilized to automatically check designs against set rules and requirements. This strategy has fewer expenses, better quality, less risk, and a quicker time to market. Let me introduce Capital Analysis, a Siemens compliance engine that seamlessly integrates with the Capital Design environment. Let’s examine its operation.
Capital Analysis facilitates thorough and automated compliance checks for EDS designers at every stage of the design and validation process. This is how the three design stages of the solution function: Voltage drop analysis, fuse selection, and connectivity verification:
It is crucial to make sure that no connections are missing for any of the vehicle combinations during the schematic design stage. Experts in EDS compliance often make use of many files in various formats to reference connectivity and configuration specifications. Even the most knowledgeable professionals run the danger of overlooking anything when they carefully review the design, which can take several months.
Capital Analysis automatically verifies that the configuration definitions adhere to the specifications and establishes connectivity between input and output devices within the Capital Design environment. Users can evaluate their designs by starting the Capital Functional Verifier in the same schematic design environment. This tool validates the connectivity of the design by loading it against a predetermined logical sequence. For simulation, users have two options:
- Turn switches on and off manually to check the correctness of the simulation and to swiftly spot and fix problems like logical disconnections.
- Set parameters for the switches and component failures you want to test, run thorough automatic tests, and examine the reports that are produced. By comparing connection to the logical criteria and analyzing every possible combination, this strategy highlights any issues that need to be reevaluated.
EDS engineers are capable of quickly locating and fixing any defects in the design before moving on to the actual design in either case.
When the project reaches the physical design stage, EDS engineers have to ensure that, in the worst-case situation, the fuses are protecting the cables. Fuse selection has historically required additional human analysis, requiring compliance specialists to evaluate component specifications and functional requirements, examine wire current data, and suggest design modifications.
Capital Analysis does away with all manual labor. By combining design and manufacturer data, performing stress tests, and offering design recommendations, the technology automates analysis and enables users to check and improve their designs considerably more quickly.
Let’s move on to voltage drop analysis, which is another common physical design assignment. At this point, the EDS group typically has to manually examine a sizable amount of data, including wire thickness, impedance, and current. The idea is to make sure that, especially in the worst-case situations, the connectivity architecture keeps the voltage high enough for all devices to function within designated input voltage ranges.
EDS engineers may dynamically flick switches to mimic particular circumstances and see how they affect voltage by using Capital Analysis. As an alternative, they can use the tool’s automation to pinpoint the worst-case situations in which component operation could be harmed by voltage decreases. Users only need to choose the proper switches to indicate which circuit segments to look at, and the Capital Components Sizer will handle many situations and generate a comprehensive report outlining any voltage compliance issues. This aids in identifying the parts that malfunction under particular circumstances and in modifying the design as needed to satisfy voltage specifications.
In order to assure compliance and improve efficiency and accuracy, engineers may continuously study, iterate, and improve electrical distribution designs within the Capital Design environment thanks to capital analysis. Engineers may make well-informed decisions that improve product safety and reduce costs by utilizing the tool to detect and resolve design concerns early on.